79 research outputs found

    Measurement uncertainty budget of an interferometric flow velocity sensor

    Get PDF
    Flow rate measurements are a common topic for process monitoring in chemical engineering and food industry. To achieve the requested low uncertainties of 0:1% for flow rate measurements, a precise measurement of the shear layers of such flows is necessary. The Laser Doppler Velocimeter (LDV) is an established method for measuring local flow velocities. For exact estimation of the flow rate, the flow profile in the shear layer is of importance. For standard LDV the axial resolution and therefore the number of measurement points in the shear layer is defined by the length of the measurement volume. A decrease of this length is accompanied by a larger fringe distance variation along the measurement axis which results in a rise of the measurement uncertainty for the flow velocity (uncertainty relation between spatial resolution and velocity uncertainty). As a unique advantage, the laser Doppler profile sensor (LDV-PS) overcomes this problem by using two fan-like fringe systems to obtain the position of the measured particles along the measurement axis and therefore achieve a high spatial resolution while it still offers a low velocity uncertainty. With this technique, the flow rate can be estimated with one order of magnitude lower uncertainty, down to 0:05% statistical uncertainty.1 And flow profiles especially in film flows can be measured more accurately. The problem for this technique is, in contrast to laboratory setups where the system is quite stable, that for industrial applications the sensor needs a reliable and robust traceability to the SI units, meter and second. Small deviations in the calibration can, because of the highly position depending calibration function, cause large systematic errors in the measurement result. Therefore, a simple, stable and accurate tool is needed, that can easily be used in industrial surroundings to check or recalibrate the sensor. In this work, different calibration methods are presented and their in uences to the measurement uncertainty budget of the sensor is discussed. Finally, generated measurement results for the film flow of an impinging jet cleaning experiment are presented

    Interferometric velocity measurements through a fluctuating interface using a Fresnel guide star-based wavefront correction system

    Get PDF
    To improve optical measurements, which are degraded by optical distortions, wavefront correction systems can be used. Generally, these systems evaluate a guide star in transmission. The guide star emits wellknown wavefronts, which sample the distortion by propagating through it. The system is able to directly measure the distortion and correct it. There are setups, where it is not possible to generate a guide star behind the distortion. Here, we consider a liquid jet with a radially open surface. A Mach–Zehnder interferometer is presented where both beams are stabilized through a fluctuating liquid jet surface with the Fresnel guide star (FGS) technique. The wavefront correction system estimates the beam path behind the surface by evaluating the incident beam angle and reflected beam angle of the Fresnel reflex with an observer to control the incident angle for the desired beam path. With this approach, only one optical access through the phase boundary is needed for the measurement, which can be traversed over a range of 250 μm with a significantly increased rate of valid signals. The experiment demonstrates the potential of the FGS technique for measurements through fluctuating phase boundaries, such as film flows or jets

    Intelligent self calibration tool for adaptive few-mode fiber multiplexers using multiplane light conversion

    Get PDF
    Space division multiplexing (SDM) is promising to enhance capacity limits of optical networks. Among implementation options, few-mode fibres (FMFs) offer high efficiency gains in terms of integratability and throughput per volume. However, to achieve low insertion loss and low crosstalk, the beam launching should match the fiber modes precisely. We propose an all-optical data-driven technique based on multiplane light conversion (MPLC) and neural networks (NNs). By using a phase-only spatial light modulator (SLM), spatially separated input beams are transformed independently to coaxial output modes. Compared to conventional offline calculation of SLM phase masks, we employ an intelligent two-stage approach that considers knowledge of the experimental environment significantly reducing misalignment. First, a single-layer NN called Model-NN learns the beam propagation through the setup and provides a digital twin of the apparatus. Second, another single-layer NN called Actor-NN controls the model. As a result, SLM phase masks are predicted and employed in the experiment to shape an input beam to a target output. We show results on a single-passage configuration with intensity-only shaping. We achieve a correlation between experiment and network prediction of 0.65. Using programmable optical elements, our method allows the implementation of aberration correction and distortion compensation techniques, which enables secure high-capacity long-reach FMF-based communication systems by adaptive mode multiplexing devices

    Holographic optogenetic stimulation with calcium imaging as an all optical tool for cardiac electrophysiology

    Get PDF
    All optical approaches to control and read out the electrical activity in a cardiac syncytium can improve our understanding of cardiac electrophysiology. Here, we demonstrate optogenetic stimulation of cardiomyocytes with high spatial precision using light foci generated with a ferroelectric spatial light modulator. Computer generated holograms binarized by bidirectional error diffusion create multiple foci with more even intensity distribution compared with thresholding approach. We evoke the electrical activity of cardiac HL1 cells expressing the channelrhodopsin-2 variant, ChR2(H134R) using single and multiple light foci and at the same time visualize the action potential using a calcium sensitive indicator called Cal-630. We show that localized regions in the cardiac monolayer can be stimulated enabling us to initiate signal propagation from a precise location. Furthermore, we demonstrate that probing the cardiac cells with multiple light foci enhances the excitability of the cardiac network. This approach opens new applications in manipulating and visualizing the electrical activity in a cardiac syncytium

    Beyond Janus Geometry: Characterization of Flow Fields around Nonspherical Photocatalytic Microswimmers

    Get PDF
    Catalytic microswimmers that move by a phoretic mechanism in response to a self-induced chemical gradient are often obtained by the design of spherical janus microparticles, which suffer from multi-step fabrication and low yields. Approaches that circumvent laborious multi-step fabrication include the exploitation of the possibility of nonuniform catalytic activity along the surface of irregular particle shapes, local excitation or intrinsic asymmetry. Unfortunately, the effects on the generation of motion remain poorly understood. In this work, single crystalline BiVO4 microswimmers are presented that rely on a strict inherent asymmetry of charge-carrier distribution under illumination. The origin of the asymmetrical flow pattern is elucidated because of the high spatial resolution of measured flow fields around pinned BiVO4 colloids. As a result the flow from oxidative to reductive particle sides is confirmed. Distribution of oxidation and reduction reactions suggests a dominant self-electrophoretic motion mechanism with a source quadrupole as the origin of the induced flows. It is shown that the symmetry of the flow fields is broken by self-shadowing of the particles and synthetic surface defects that impact the photocatalytic activity of the microswimmers. The results demonstrate the complexity of symmetry breaking in nonspherical microswimmers and emphasize the role of self-shadowing for photocatalytic microswimmers. The findings are leading the way toward understanding of propulsion mechanisms of phoretic colloids of various shapes

    Medical Imaging of Microrobots: Toward In Vivo Applications

    Get PDF
    Medical microrobots (MRs) have been demonstrated for a variety of non-invasive biomedical applications, such as tissue engineering, drug delivery, and assisted fertilization, among others. However, most of these demonstrations have been carried out in in vitro settings and under optical microscopy, being significantly different from the clinical practice. Thus, medical imaging techniques are required for localizing and tracking such tiny therapeutic machines when used in medical-relevant applications. This review aims at analyzing the state of the art of microrobots imaging by critically discussing the potentialities and limitations of the techniques employed in this field. Moreover, the physics and the working principle behind each analyzed imaging strategy, the spatiotemporal resolution, and the penetration depth are thoroughly discussed. The paper deals with the suitability of each imaging technique for tracking single or swarms of MRs and discusses the scenarios where contrast or imaging agent's inclusion is required, either to absorb, emit, or reflect a determined physical signal detected by an external system. Finally, the review highlights the existing challenges and perspective solutions which could be promising for future in vivo applications
    corecore